Main page
Request for a commercial offer
Send message Order a callback Application for equipment
 

Infusion syringe pump
Sino SN-50C6

  • Infusion syringe pump SN-50C6
  • Infusion syringe pump SN-50C6
  • Infusion syringe pump SN-50C6
  • Infusion syringe pump SN-50C6
  • Infusion syringe pump SN-50C6
  • Infusion syringe pump SN-50C6
  • Infusion syringe pump SN-50C6
  • Infusion syringe pump SN-50C6

Send a request
to clarify the cost,
terms and delivery terms Sino SN-50C6


Update
 

 

Single channel syringe pump is a the most common see and popular iv syringe driver pump among all models. It features stable quality, easy to operate, and automatic calibration and most importantly accurate injection. Various modes support include Time mode, Speed mode, body weight mode and drug library mode. The model with R is machine with smart WIFI function.

The SN infusion syringe pump is designed for accurate dosing of drugs administered to a patient. This type of pump can be used to equip an anesthesiologist's workplace in the operating room, intensive care and resuscitation units, premature infants, neonatal intensive care units, chemotherapy and other places where precise dosage of drugs is used per unit of time. This device allows titration of drugs for anesthesia, vasoactive and inotropic drugs, parenteral nutrition, chemotherapy and other medicines.

Technical characteristics

Syringes5, 10, 20, 30, 50 ml of calibrated syringes
Flow rate0.1–1500 ml/h (specified value 0.1 999.9 ml/h, 0.1 ml/h step)50 ml syringe
0.1–900 ml/h (0.1 ml/h step)30 ml syringe
0.1–600 ml/h (0.1 ml/h step)20 ml syringe
0.1–400 ml/h (0.1 ml/h step)10 ml syringe
Purge rate1500 ml/h50 ml syringe
900 ml/h30 ml syringe
600 ml/h20 ml syringe
400 ml/h10 ml syringe
АlarmOcclusion, Nearly empty, Finish, Syringe dislocated, Plunger/Clutch disengaged, Battery low, Battery exhausted, Power cable disconnected, Flow rate over limit, Volume over limit, System error, Non-operation time over
Display range of volume delivered0.1 ~ 9999 ml (0.1 ~ 999.9 ml,0.1 ml step) (1000 ~ 9999 ml, 1 ml step)
Setting of delivery limit0.1 ~ 9999 ml (0.1 ~ 999.9 ml,0.1 ml step) (1000 ~ 9999 ml, 1 ml step)
Occlusion detection pressureH: 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27±kgf/cm2
C: 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13±kgf/ cm2
L: 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13±kgf/ cm2
Accuracy of flow rate (Nominal value)Accuracy including syringe: with in ±2% Mechanical accuracy: with in ±1%
PowerAC110-220V± 10%,50/60 Hz±1 Hz Inner NiMH battery: DC12 V
Continuous operation time of battery: over 6 hours for one channel, over 4 hours for dual channel when battery is recharged for 12 hours, at flow rate of 5 ml/h.
Operation conditionsAmbient temperature: 5 to 40 °C
Relative humidity: 20% to 80%/td>
Storage conditionsAmbient temperature: 5 to 40 °C
Relative humidity: ≤95%
Electric shock protection/classClass I and internal power supply: Type CF, Continuous operation
Waterproof levelIPX 4
Weight /class2.25 kg (with clamp base)/td>
Dimensions306 mm (Width) x 135 mm (Height) x 127 mm (Depth)

Function

Calibrating syringe automaticallyFast rate control
Identifying syringe size automatically«Purge» button activate safe protection
3-level occlusion alarm limits settingFlow rate setting button lock
Delivered volume inquiryAbundant optic and sound alarm
Limits settingAC and internal power indication
Automatically reducing impact dose release after occlusion Standard RS232 interface
KVO flow rate (0.1–1.0 ml/h Adjustable)1000 history records
Wireless communication (SN-50C66R)Multi-direction clamp for either horizontal or vertical fixation