Infusion syringe pump
SN-А
The SN infusion syringe pump is designed for accurate dosing of drugs administered to a patient. This type of pump can be used to equip an anesthesiologist's workplace in the operating room, intensive care and resuscitation units, premature infants, neonatal intensive care units, chemotherapy and other places where precise dosage of drugs is used per unit of time. This device allows titration of drugs for anesthesia, vasoactive and inotropic drugs, parenteral nutrition, chemotherapy and other medicines. The infusion pump is characterized by high accuracy of drug infusion, stability of the rate of administration, and the possibility of micro dosing of administered drugs.
Technical characteristics
Infusion Mode | SN-A1A: Speed Mode, Time Mode, Body-weight Mode SN-A1: Speed Mode, Time Mode, Body-weight Mode, Micro Mode SN-A2: Time Mode, Body-weight Mode, Micro Mode, Sequence Mode, Loading Mode, Gradient Mode SN-A2T: Time Mode, Body-weight Mode, Micro Mode, Sequence Mode, Loading Mode, Gradient Mode, TIVA Mode |
Syringes | 5, 10, 20, 30, 50/60 ml |
Accurancy of flow rate | ±2% |
Present Volume | 0.1–9999.99 ml, increment 0.01 ml |
Delivered Volume | 0.1–9999.99 ml, increment 0.01 ml |
Flow rate | 50ml Syringe — 0.1 ml/h–1500 ml/h 30ml Syringe — 0.1 ml/h–900 ml/h 20ml Syringe — 0.1 ml/h–600 ml/h 10ml Syringe — 0.1 ml/h–400 ml/h 5ml Syringe — 0.1 ml/h–150 ml/h 0.1–99.99 ml/h, increment 0.01 ml/h 100–999.9 ml/h, increment 0.1 ml/h 1000–1500 ml/h, increment 1 ml/h |
Аlarms | Liquid Residue Alarm,Injection Completed KVO Alarm, KVO Completed Alarm, Tube Occlusion Alarm, Net Power Not Connected Alarm, System Power Failure Alarm, No Operation Timeout Alarm, Syringe Specification Error Alarm, Push Rob Off Alarm, Overspeed Alarm, Battery Low Alarm, System Fault Alarm, Extension Tube Alarm. |
KVO rate | 0.1–5 ml/h |
BOLUS | 50ml Syringe: 5ml/h–1500 ml/h, default: 1500 ml/h 30ml Syringe: 5 ml/h–900 ml/h, default: 900 ml/h 20ml Syringe: 5 ml/h–600 ml/h, default: 600 ml/h 10ml Syringe: 5 ml/h–400 ml/h, default: 400 ml/h 5ml Syringe: 5 ml/h–150 ml/h, default: 150 ml/h |
Infusion Mode | SN-A1A: Speed Mode, Time Mode, Body-weight Mode SN-A1: Speed Mode, Time Mode, Body-weight Mode, Micro Mode SN-A2: Time Mode, Body-weight Mode, Micro Mode, Sequence Mode, Loading Dose Mode, Gradient Mode SN-A2T: Time Mode, Body-weight Mode, Micro Mode, Sequence Mode, Loading Dose Mode, Gradient Mode, TIVA Mode |
History | More than 2000 pcs |
Special Function | Supporting pump stackable with working station, Relay infusion, Keypad Lock, Adjusting rate on infusion, Release pressure automatically, Extension tube off alarm, Multi-drection fixing clamp, Night mode, Volume adjustment, Dynamic pressure detector, Drug library |
Communication | RS485, WIFI |
Protection Class | Class II, Type CF, IP33 |
Dimension/ Weight | 287x168x82 (mm), 2.1 KG |
Interface | DC Power interface, General Communication Interface (Nurse call, RS485) |
Power | a. AC Adapter Input: 100-240 Va. C, 50/60 Hz, 40VA Output: 15Vd.c,2.0 F b. DC Power: DC 12V c. Battery: 7.4 V Li, 2600 mAh or 5200mAh Rechaining time: Approx 8 hours when power on; Approx 4 hours when power off Battery operating time: 10 hours @5200mAh at 5ml/h 5 hours @2600mAh at 5ml/h |
Environment | Operation condition: Ambient Temperature: +5°C–40°C Relative Humidity: 15%–95% (Non-condensed) Pressure: 57.0 kPa–106 kPa, ≤ 3000 m Altitude Storage condition: Ambient Temperature: –40°C...+70°C, Relative Humidity: 10%–98% (Non-condensed) Pressure: 50.0 kPa–106 kPa |